In Short
Generator enclosures for data centers and commercial buildings house the standby sets outdoors, on a yard, a roof or a car park, and keep them quiet, dry, secure and easy to service. A data center generator enclosure is usually one of a long row of identical units, while a commercial generator enclosure is more often a single unit that has to fit a tight space and look acceptable next to a building people use. Send AXON the generator set, the site layout and the noise requirement, and AXON designs the enclosure.
A data center and an office building both need standby power, and both usually put the generator outside in an enclosure. The two jobs look alike on a drawing and turn out quite different on site. The data center wants a row of identical units that behave the same and can be serviced one at a time. The commercial building wants one generator enclosure that fits a corner nobody else wanted, does not annoy the neighbours and does not spoil the look of the place. This guide covers what each of them asks of the enclosure, in plain words.
A Data Center Generator Enclosure Is Rarely Alone
On a data center the generator yard is laid out like a street: the same enclosure, repeated along the building, each one feeding its part of the site. What matters there is that every unit is the same. The same layout inside, the same doors in the same places, the same connections for fuel and cables. Operators train their technicians on one unit and expect the next one to match it, and the commissioning team tests them one after another.
Standing close together brings its own problems. Warm air from one enclosure must not end up in the inlet of the next, exhaust must leave the row cleanly, and the noise of a whole yard running at once is what the neighbours hear, not the noise of one set. These are questions for the whole yard, and they are best answered before the first enclosure is built.
Service While the Other Sets Stand Ready
A data center does not switch off its standby power for maintenance. One set is taken out of readiness while the rest stay available, so the technicians work inside one enclosure with the neighbouring sets able to start at any moment. The enclosure has to make that safe and quick: room to walk around the set, doors that open fully in the space between units, lighting, and a way to get large parts in and out without moving the enclosure next door.
Yard layouts get this wrong more often than anything else. A drawing that fits the units tightly into the yard can leave no room to open the doors between them, and the gap only shows when the first service visit arrives.
Commercial Generator Enclosures on Roofs, Yards and Car Parks
Office blocks, hotels, shopping centres, hospitals and residential towers rarely have a generator yard. The commercial generator enclosure goes where there is space: a service yard, a corner of the car park, a roof, a strip of ground beside the loading bay. Each place sets its own conditions. A roof needs to know what the structure can carry and how the unit gets up there. A car park needs protection from vehicles. A yard used for deliveries needs the enclosure to stay out of the way of the lorries.
People are close by, too. Windows, terraces and the street are often within sight and earshot, so the noise from the enclosure, the exhaust and the air openings is directed away from them where possible, and the access doors and fuel filling point are kept where only staff will use them.
Planners, Neighbours and the Look of the Building
For a commercial building the enclosure is part of the street scene, and planners often have a view on it. Colour, height and the line of the roof can matter as much as the noise, and some sites ask for cladding or a screen so the unit matches the building. Security is a real concern on sites open to the public: locks, no easy way to climb onto the roof, and nothing on the outside that invites tampering.
On both kinds of site the noise requirement usually comes from the local authority or the planning conditions, and it is far easier to build the enclosure for it at the start than to add treatment once the neighbours have complained. AXON designs and builds generator enclosures and containers around generator sets of any make, for single sets and for whole rows. Send the generator set, a site plan with the neighbours marked and the noise requirement, and AXON works out the enclosure and prepares the proposal.
What this guide covers
- Why data center generator enclosures are built as identical units in a row
- Warm air, exhaust and noise from a whole generator yard
- Service access while the neighbouring sets stay ready to start
- Commercial generator enclosures on roofs, yards and car parks
- Planning, appearance and security on sites open to the public
- Building in the noise requirement from the start
What to send with an enquiry
- Generator set make and model, and the number of sets
- A site plan showing where the enclosures stand and where the neighbours are
- The noise requirement from the authority or the planning conditions
- For a roof: what the structure can carry and how the unit is lifted
- How the fuel is supplied and where the cables run
- Any requirement on colour, cladding, screening or security
Questions we are often asked
What is a data center generator enclosure?
The outdoor housing of one standby generator set on a data center site, usually one of a row of identical units, built for quiet running, safe service and the same layout in every unit.
How does a commercial generator enclosure differ from one for a data center?
A commercial site usually has a single unit in a tight space close to people, so fitting the space, noise towards windows and the street, appearance and security weigh more. A data center has many units, and sameness and service access matter most.
Can a generator enclosure be installed on a roof?
Often, yes. The roof has to carry the unit, there must be a way to lift it up, and the noise and exhaust have to be kept away from windows and terraces nearby.
Can a generator enclosure be made to match the building?
Yes. The colour can be chosen, and cladding or a screen can be added where the planners or the owner want the unit to blend in.
What does AXON need to design generator enclosures for a site?
The generator set, the number of sets, a site plan with the neighbours marked and the noise requirement. AXON designs the enclosure for generator sets of any make.
Products
Further reading
- Data Center Generator Emissions and Noise: SCR, Silencers and Acoustic Enclosures
- Containerized Generator Sets for Data Centers: Faster Deployment, Predictable Performance
- What Is a Generator Enclosure or Container, and What Does It Include?
- Acoustic Enclosure, Container or Canopy: Which Housing for a Diesel Generator?
- Data Center Backup Generator Requirements: Ratings, Redundancy, Fuel, Noise and Emissions